COD Probe Archives | Water Quality Sensors https://opticaldosensor.com/product-tag/cod-probe/ OPS Tue, 03 Mar 2026 08:04:36 +0000 en-US hourly 1 https://opticaldosensor.com/wp-content/uploads/2022/03/cropped-cropped-LOGO-1-32x32.png COD Probe Archives | Water Quality Sensors https://opticaldosensor.com/product-tag/cod-probe/ 32 32 DS500 Online COD BOD TSS Sensor Analyzer https://opticaldosensor.com/product/real-time-online-cod-bod-tss-monitoring-sensor-probe/ Thu, 28 Mar 2024 06:29:54 +0000 https://opticaldosensor.com/?post_type=product&p=3463 The DS500 Series Online COD, BOD, and TSS Sensor Analyzer can be used to detect the Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), and Total Suspended Solids (TSS) values of water quality.

Model: DS500
Measurement Range: COD 0 ~ 500 mg/L; COD 0 ~ 1000 mg/L;
COD 0 ~ 2000 mg/L; COD 0 ~ 5000 mg/L.
Detection Principle: UV245nm UV Optics
Output Signal: RS-485、MODBUS Protocol
Cable Length: Standard 5 meters, longer can be customized

Get A Quote Now

The post DS500 Online COD BOD TSS Sensor Analyzer appeared first on Water Quality Sensors.

]]>
Overview

COD, BOD, and TSS are important water quality parameters for wastewater treatment operations. The online COD BOD TSS Sensor Analyzer can be used to detect the Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), and Total Suspended Solids (TSS) values of water quality.

The DS500 series Online COD BOD TSS Sensor Analyzer is a new generation of environmental protection-type sensors launched by OPS. It is based on the UV absorption principle, reagent-free, pollution-free, more economical, and environmentally friendly. Small size, more convenient installation, and online continuous water quality monitoring. Automatic compensation for turbidity interference, automatic cleaning devices, and even long-term monitoring still have excellent stability. It can be used in harsh environments, and the monitoring data is stable and reliable. Multiple path length options are available to ensure our clients have the detection range that meets their wastewater monitoring demands.

Get A Quote Now

Online COD BOD TSS Sensor Analyzer Principle

Many organic substances dissolved in water absorb ultraviolet light. Therefore, the total amount of organic pollutants in water can be measured by measuring the absorption of these organic substances by ultraviolet light at a wavelength of 254 nm. DS500 series sensors use two light sources, one 254nm ultraviolet light and one 850nm infrared light, which can automatically compensate for the optical path attenuation and turbidity effects, thus achieving more stable and reliable measurement values. The sensors measure organics in a multi-dimensional way that results in improved correlations to water quality parameters such as BOD, COD, and TSS.

Features of DS500 series Online COD BOD TSS Sensor Analyzer

-Digital sensors, RS-485 output, Modbus protocol;

-With automatic cleaning function and few maintenance;

-No chemical reagents, no secondary pollution;

-Direct immersion COD measurement without sampling;

-Quick response time and precision for COD continuous measurement;

-Real-time data transmission allows you to get timely and accurate data on monitoring water;

-Corrosion-resistant shell, easy to install;

-Proven UVC LED technology, long lifetime, stable and instant measurement;

-Measurement of parameters such as COD, TOC, TSS, and temperature;

-Adopts low power consumption design and has the characteristics of anti-interference performance;

-Automatic compensation for turbidity interference for excellent test performance.

Technology Parameter

Product NameCOD Sensor/ Chemical Oxygen Demand Sensor
ModelDS500
Detection principleUV245nm UV Optics
Measurement range
DS501
(6 mm gap)
COD 0 ~ 500 mg/L
BOD equiv. 0 ~ 200 mg/L
TSS equiv. 0 ~ 500 mg/L
Measurement range
DS501
(6 mm gap)
COD 0 ~ 1000 mg/L
BOD equiv. 0 ~ 500 mg/L
TSS equiv. 0 ~1000 mg/L
Measurement range
DS501
(6 mm gap)
COD 0 ~ 2000 mg/L
BOD equiv. 0 ~ 1000 mg/L
TSS equiv. 0 ~2000 mg/L
Measurement range
DS502
(2 mm gap)
COD 0 ~ 5000 mg/L
BOD equiv. 0 ~ 2000 mg/L
TSS equiv. 0 ~3000 mg/L
Measurement accuracy3-5%
Resolution0.01mg/L
Output signalRS-485、MODBUS protocol
Calibration method2 points
Waterproof levelIP68
Under pressure1bar
Product materialSS316/Titanium alloy
Product Size∅46×234mm
Power informationDC 6~12V,Current <10mA
Cable lengthStandard 5 meters, longer can be customized

Get A Quote Now

Application Areas of Online COD BOD TSS Sensor Analyzer

-Surface Water Pollution Detection and Monitoring

-Urban Well Monitoring

-River & lake Water Quality Monitoring

-Sewage Treatment Plant Water Quality Monitoring

-Fishery Water Quality Pollution Monitoring

-Fish farming, aquaculture

-Swimming Pool Water Quality Monitoring

-Industrial and Mining Enterprises, Detection of Urban Sewage Discharge

-Water quality monitoring of petrochemical, chemical, power generation, pharmaceutical, food, electronic, water plant, etc

-Water quality inspection of urban parks

-Smart city water quality detection

-Urban wastewater treatment: detecting organic load variations during input/ treatment process/ output.

-Treatment of industrial effluents

-Drinking water: monitoring Organic matter in raw water, oxidation process, coagulation, activated carbon filtration.

COD Sensor Application

OPS COD Sensors Use sites

OPS COD Sensors Use sites 1

OPS COD Sensors Use sites 2

OPS COD BOD TSS Monitoring Sensor Use sites 3

Get A Quote Now

FAQs about Online COD BOD TSS Sensor Analyzer

1. What is COD, BOD, and TSS?

COD, BOD, and TSS are commonly used terms in environmental science and wastewater treatment.

COD: Chemical Oxygen Demand

COD measures the amount of oxygen required to chemically oxidize organic and inorganic matter in water. It is a measure of the pollution load, particularly the amount of organic pollutants, in water. COD is often used as an indicator of water quality and pollution levels in industrial and municipal wastewater.

BOD: Biochemical Oxygen Demand

BOD refers to the amount of dissolved oxygen consumed by microorganisms while decomposing organic matter in water. It indicates the level of organic pollution in water and the amount of oxygen needed for aerobic biological processes to break down organic pollutants. BOD is a key parameter in assessing the effectiveness of wastewater treatment processes and the overall health of aquatic ecosystems.

TSS: Total Suspended Solids

TSS represents the concentration of solid particles suspended in water, including organic and inorganic matter. These particles can include silt, sediment, organic debris, and other materials that are not dissolved in the water. It is an important parameter in assessing water clarity, sedimentation, and overall water quality, particularly in evaluating the effectiveness of sediment control measures and wastewater treatment processes.

2. Why Measure Chemical Oxygen Demand (COD)?

(1) Assessing Water Quality: COD measurement provides valuable information about the organic pollution level in water bodies. High COD levels indicate the presence of organic contaminants, which can adversely affect aquatic ecosystems and human health if not properly treated.

(2) Monitoring Wastewater Treatment Efficiency: In industrial and municipal wastewater treatment plants, measuring COD helps operators assess the efficiency of treatment processes. By monitoring COD levels in influent and effluent wastewater, operators can determine how effectively organic pollutants are being removed during treatment.

(3) Compliance with Regulations: Many environmental regulations set limits on the allowable COD levels in wastewater discharges. Industries and municipalities must comply with these regulations to avoid fines and penalties. Regular COD monitoring ensures compliance with regulatory requirements.

(4) Optimizing Treatment Processes: COD data allows wastewater treatment plant operators to optimize treatment processes for maximum efficiency. By tracking COD levels and adjusting treatment parameters accordingly, operators can improve the removal of organic pollutants and minimize environmental impact.

(5) Predicting Oxygen Depletion: High COD levels in water bodies can lead to oxygen depletion as microorganisms decompose organic matter, leading to conditions such as hypoxia or anoxia, which can harm aquatic life. Measuring COD helps predict and prevent such oxygen depletion events.

(6) Research and Development: COD measurement is also valuable in research and development efforts aimed at developing more efficient and sustainable wastewater treatment technologies. Researchers use COD data to evaluate the performance of new treatment methods and technologies.

3. What Processes Require Chemical Oxygen Demand (COD) Monitoring?

-Municipal and industrial wastewater treatment

-Primary Treatment.

-Secondary Treatment.

-Discharge limits.

-Continuous monitoring of organic matter load in the sewage treatment process.

-On-line real-time monitoring of influent and outflow water of the wastewater treatment.

4. Why is COD an Important Water Quality Parameter?

COD is an important water quality parameter and is used in a wide range of applications, including:

1, To confirm wastewater discharge and the waste treatment procedure meets criteria set by regulators;

2, To quantify the biodegradable fraction of wastewater effluent – ratio between BOD and COD;

3, COD or BOD measurements are also used as an indicator of the size of a wastewater treatment plant required for a specific location.

5. What to Consider When Selecting a Method to Analyze Oxygen Demand?

-Specific test application

-The oxidant to be used

-Time to completion

-Accuracy and precision of the measurement

VIDEOS


Related Articles

Top 9 Water Quality Sensors For Wastewater Treatments

Application of COD Sensor in sewage treatment

28 sets COD Sensors were Ready to ship to India for sewage treatment

Various Applications of OPS Chemical Oxygen Demand sensors

What are Online COD BOD TSS analyzers?

Get A Quote Today

The post DS500 Online COD BOD TSS Sensor Analyzer appeared first on Water Quality Sensors.

]]>
Chemical Oxygen Demand COD Sensor https://opticaldosensor.com/product/cod-sensor/ Wed, 18 Mar 2020 21:48:44 +0000 https://opticaldosensor.com/product/skin-whitening-toner/ Model: DS500
Measurement Range:
COD 0 ~ 500 mg/L
COD 0 ~ 1000 mg/L
COD 0 ~ 2000 mg/L
COD 0 ~ 5000 mg/L

The post Chemical Oxygen Demand COD Sensor appeared first on Water Quality Sensors.

]]>
Chemical Oxygen Demand COD Sensor Overview

DS500 Series Online Chemical Oxygen Demand COD Sensor from OPS is a next-generation, eco-friendly solution for water quality monitoring. With no reagents required, it creates zero secondary pollution—making it both cost-effective and environmentally responsible. Its compact design allows for quick installation, while real-time online monitoring ensures continuous oversight of water quality. Featuring automatic turbidity compensation and a self-cleaning function, the DS500 delivers long-term stability with minimal maintenance.

DS500 Chemical Oxygen Demand COD Sensor

Measuring Principle

The DS500 series is built on advanced UV absorption technology. Since many organic substances in water absorb ultraviolet light at 254 nm, the sensor can accurately measure the levels of organic pollution. To ensure precision, the DS500 uses a dual-light source—254 nm UV and 850 nm infrared—which automatically corrects for turbidity and optical path disturbances. The result is highly stable, reliable readings. By capturing organics in multiple dimensions, the DS500 provides stronger correlations with key indicators such as BOD, COD, and TSS, giving you a more complete and accurate picture of water quality.

Key Features of the Online COD Sensor

Eco-Friendly & Cost-Saving: Works without reagents—no chemicals, no pollution, just a smarter and greener solution.

All-in-One Monitoring: Measure COD, BOD, TSS, TOC, and more with a single sensor.

Reliable Accuracy: Automatic turbidity compensation ensures clear, dependable results every time.

Fast & Efficient: Advanced optical technology delivers quick, stable, and exact measurements.

RS-485 Output Signal: It is equipped with an RS-485 interface that allows easy and fast sensor configuration via Modbus. It can be easily connected to a monitoring system. DSMC5100 can be equipped with it to read real-time monitoring data, and the data storage function provides users with a basis for analyzing the data.

Technical Parameter

Product NameCOD Sensor/ Chemical Oxygen Demand Sensor
ModelDS500
Detection principleUV245nm UV Optics
Measurement range
DS501
(6 mm gap)
COD 0 ~ 500 mg/L
BOD equiv. 0 ~ 200 mg/L
TSS equiv. 0 ~ 500 mg/L
Measurement range
DS501
(6 mm gap)
COD 0 ~ 1000 mg/L
BOD equiv. 0 ~ 500 mg/L
TSS equiv. 0 ~1000 mg/L
Measurement range
DS501
(6 mm gap)
COD 0 ~ 2000 mg/L
BOD equiv. 0 ~ 1000 mg/L
TSS equiv. 0 ~2000 mg/L
Measurement range
DS502
(2 mm gap)
COD 0 ~ 5000 mg/L
BOD equiv. 0 ~ 2000 mg/L
TSS equiv. 0 ~3000 mg/L
Measurement accuracy3-5%
Resolution0.01mg/L
Output signalRS-485、MODBUS protocol
Calibration method2 points

Specifications

Waterproof levelIP68
Under pressure1bar
Product materialSS316/Titanium alloy
Product Size∅46×234mm
Power informationDC 6~12V,Current <10mA
Cable lengthStandard 5 meters, longer can be customized

DS500 COD Sensor Installation Cases

OPS COD Sensors Cases

OPS COD Analyzer Cases

Applications Of  COD Sensors

COD sensors play a vital role across a wide range of industries and environmental management sectors. Below are some of the key areas where they are commonly used:

COD Sensor Application

-Wastewater Treatment Plants
Treatment facilities use COD sensors to continuously monitor incoming wastewater and verify that the treated effluent meets regulatory standards. Accurate COD measurements allow operators to fine-tune processes and reduce pollution effectively.

-Industrial Effluent Monitoring
Industries such as food processing, textiles, and chemicals generate significant wastewater. COD sensors help these facilities monitor effluent quality and ensure compliance with environmental regulations before discharge.

-Environmental Monitoring
Government and environmental agencies deploy COD sensors to track pollution levels in rivers, lakes, and coastal waters. Elevated COD readings can signal the presence of harmful organic pollutants that threaten aquatic ecosystems.

-Municipal Water Systems
Municipalities use COD sensors to safeguard both drinking water and wastewater systems. Monitoring COD levels helps detect organic contamination early, enabling timely corrective action to maintain public health and water quality.

-Aquaculture
In fish farming and other aquaculture operations, COD sensors are essential for maintaining healthy water conditions. High COD levels may indicate deteriorating water quality that could endanger aquatic life.

Advantages of Using COD Sensors

COD sensors provide significant benefits for both industries and environmental monitoring organizations. Some of the key advantages include:

Real-Time Data: Continuous, real-time monitoring enables faster and more informed decision-making in wastewater treatment plants and industrial operations.

Cost Efficiency: Regular monitoring helps facilities avoid costly fines and penalties by ensuring compliance with environmental regulations.

High Accuracy: Advanced COD sensors deliver precise measurements, minimizing errors and improving the reliability of water quality assessments.

Automation-Friendly: Modern COD sensors can be seamlessly integrated into automated systems, simplifying the management of large-scale water treatment processes.

Installation

DS500 COD Sensor Installation Method

Calibration of DS500 COD Sensors

Step 1: Select the theoretical value according to the range, e.g., if the range is 100mg/l, then choose 12 for theoretical value 1; choose 84 for theoretical value 2.

Step 2: Before starting this, Reset K=1, B=0. Put the sensor into the test solution of 12mg/l, wait for the test data to stabilize, then enter the average value of the measured value as the measured value 1. Place the sensor in another test solution of 84mg/l, wait for the test data to stabilize, and enter the average of the measured values as the measured value 2.

Step 3: Click OK via the calibration help software. You will get the new K, B values, and save the new K, B values in the testing software.

COD calibration is completed.

FAQs About COD Sensor

1, What Is COD and BOD?

COD (Chemical Oxygen Demand) measures the total quantity of oxygen required to chemically oxidize organic and inorganic substances in water.

BOD (Biochemical Oxygen Demand) measures the amount of oxygen that microorganisms consume while breaking down organic matter in water over a period (usually 5 days at 20°C).

Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD) are essential parameters used to measure the organic pollution in water bodies. COD quantifies the amount of oxygen required to chemically oxidize organic matter in water, using strong chemical oxidants under acidic conditions. It provides a measure of the total organic content, including both biodegradable and non-biodegradable organic matter.

BOD measures the amount of oxygen consumed by microorganisms to biologically decompose organic matter in water over a specific period, typically 5 days (BOD5). It indicates the biodegradable organic content and is a key indicator of water quality, reflecting the potential for oxygen depletion in aquatic environments.

Both COD and BOD are crucial for assessing the impact of wastewater and industrial effluents on receiving water bodies. High levels of COD and BOD can lead to eutrophication, depletion of dissolved oxygen, and adverse effects on aquatic life. Monitoring these parameters helps in managing wastewater treatment processes and ensuring compliance with environmental regulations.

2, What is BOD vs COD vs TOC?

BOD (Biochemical Oxygen Demand): Indicates the biologically degradable portion of organic matter.

COD (Chemical Oxygen Demand): Represents both biodegradable and non-biodegradable (but oxidizable) organics.

TOC (Total Organic Carbon): Measures all carbon in organic compounds; doesn’t directly reflect oxygen demand but gives insight into organic pollution.

3, Why Do We Measure COD in Water?

We measure Chemical Oxygen Demand (COD) in water because it’s a critical indicator of water quality and helps in multiple key areas. Here’s how it connects to each of the points you listed:

  • Pollution Control:

-COD measures the amount of oxygen required to chemically oxidize organic and inorganic matter in water.

-High COD indicates high pollution levels—often from industrial discharges or sewage—helping authorities track pollution sources.

  • Wastewater Treatment

-COD testing helps assess how effective a treatment process is at removing organic matter.

-It’s often used alongside BOD (Biochemical Oxygen Demand) to monitor treatment efficiency and process performance.

  • Regulatory Compliance

-Environmental agencies set COD limits for effluent discharge into natural water bodies.

-Industries and treatment plants must regularly test COD to ensure their discharge meets legal requirements.

  • Environmental Impact Assessment

-COD data provides insight into the potential impact of a discharge or activity on aquatic ecosystems.

-It’s used during project planning to predict and minimize harm to nearby water bodies.

  • Water Quality Management

-Authorities monitor COD to manage and maintain healthy water systems—rivers, lakes, reservoirs, etc.

-It helps in prioritizing clean-up operations and resource allocation.

  • Resource Management

-By tracking COD, water managers can determine the availability of clean water for reuse, irrigation, industrial use, or recreation.

-It supports the sustainable use of water resources, especially in water-scarce regions.

4, What is a COD Sensor?

A COD sensor is a device used to measure the Chemical Oxygen Demand (COD) in water, typically through UV-visible light absorption or reagent-based methods. These sensors enable real-time monitoring of organic pollution levels. A high COD value indicates a significant presence of organic pollutants that consume oxygen during decomposition, making it a key parameter for assessing water quality.

COD sensors have become indispensable for industries that manage wastewater, including manufacturing plants, power stations, and water treatment facilities. By continuously monitoring COD levels, these industries can evaluate water quality, optimize treatment processes, and ensure compliance with environmental regulations before discharging water back into the environment.

5, What is UV254?

UV254 is a water quality test parameter that quickly measures the organic matter in water. The measurement technique works by shining ultraviolet light (UV) at 254 nm through a quartz cell that contains a representative water sample. Most commonly, the cell is 1 cm (10 mm) but can vary depending on the application and water quality.

Organic compounds, specifically those that contain aromatic rings or unsaturated carbon bonds (double or triple) in their molecular structure, absorb a portion of the UV light as it passes through the water sample. Since the intensity of the light source is known, a detector on the other side of the cell is used to measure the amount of light absorbed by organic compounds present in the sample.

UV254 is typically expressed as either UV absorbance (UVA) per cm (cm-1) or UV transmittance (UVT) %. In some cases, UV254 is referred to as the Spectral Absorption Coefficient (SAC254).

UV254 and UVT are both valuable water quality measurements for many applications, including UV disinfection performance monitoring, raw water monitoring for event detection, coagulation control, and DBP precursor monitoring. The measurement method is simplistic and does not involve the use of reagents. There are multiple ways in which UV254 or UVT can be measured, including: continuously in real-time with a bypass analyzer or submersible probe sensor, grab samples throughout the plant with a portable test meter, or in the laboratory with a test meter or benchtop spectrophotometer.

6, Why is COD Higher Than BOD in Wastewater?

COD includes all chemically oxidizable substances, both biodegradable and non-biodegradable.

BOD measures only the oxygen used by microbes to break down biodegradable material.

Therefore, COD is typically higher than BOD, especially in industrial wastewater or where non-biodegradable organics are present.

7, Why is measuring Chemical Oxygen Demand (COD) essential in water quality monitoring?

COD represents the amount of oxygen required to chemically oxidize organic compounds present in a water sample. It serves as a critical indicator of the concentration of organic pollutants, providing insight into the potential impact on aquatic ecosystems and the efficiency of wastewater treatment processes. By quantifying the oxygen demand, COD measurements help evaluate organic load, assess compliance with environmental regulations, and guide operational adjustments in industrial and municipal treatment systems.

8, How to Choose the Right COD Sensor?

Choosing the right COD sensor depends on several factors, including the application, water quality, and budget. Here are some factors to consider:

-Water Quality

If you’re dealing with very dirty or polluted water, an optical COD sensor might be the better choice as it can handle a wider range of pollutants. For cleaner water or industrial applications, electrochemical sensors may offer better precision.

-Measurement Range:

Ensure that the sensor can measure the COD levels you expect to encounter in your water samples.

-Installation Type

COD sensors can either be inline (placed directly into the water stream) or offline (where samples are taken for analysis). Inline sensors are better for continuous monitoring, while offline sensors might be more suited for periodic checks.

-Budget

Optical COD sensors tend to be more expensive than electrochemical ones but may require less maintenance in the long run. Evaluate both upfront costs and ongoing maintenance expenses when choosing a sensor.

-Maintenance Requirements

Consider how often the sensor will need maintenance or calibration. Some COD sensors, especially electrochemical models, require more frequent maintenance, while optical sensors tend to need less attention.

-Data Integration

Many modern COD sensors come with digital output options, making it easier to integrate them with SCADA (Supervisory Control and Data Acquisition) systems or other digital monitoring systems.

Videos

 

 

Related Blogs

Top 9 Water Quality Sensors For Wastewater Treatments

Application of COD Sensor in sewage treatment

28 sets COD Sensors were Ready to ship to India for sewage treatment

Various Applications of OPS Chemical Oxygen Demand sensors

What are Online COD BOD TSS analyzers?

Send An Enquiry

The post Chemical Oxygen Demand COD Sensor appeared first on Water Quality Sensors.

]]>